01.01.2010
Übersicht PV- Anlagen
| *S = 0°, W = +90°, O = -90° | |||||||||||||
| Standort | Bj. | Lage* | Neigung | Modultyp | Leistung | Wechselrichter, Typ und Anzahl | Jahreserträge: | ||||||
| 2004 | 2005 | 2006 | 2007 | 2008 | 2009 | ||||||||
| [°] | [°] | [kWp] | |||||||||||
| Wilhelmshaven | 2004 | 0 | 30 | 14 x SSEC Multi Crystal 165 | 2,31 | 1 x SMA SB 2100 TL | kWh | 54 | 2463 | 2275 | 2297 | 2299 | 2328 |
| kWh/kWp | 23 | 1066 | 985 | 994 | 995 | 1007 | |||||||
| Wilhelmshaven | 2005 | 55 | 35 | 12 x Sanyo HIT 200 | 2,4 | 1 x SMA SB 2100 TL | kWh | 1175 | 2071 | 2138 | 2053 | 2200 | |
| kWh/kWp | 490 | 862 | 890 | 855 | 916 | ||||||||
| Oldenburg | 2005 | 50 | 43 | 28 x ASE-165-GT-FT-MC | 4,62 | 1 x Fronius IG 40 | kWh | 115 | 3679 | 3782 | 3768 | 3820 | |
| kWh/kWp | 25 | 796 | 818 | 815 | 827 | ||||||||
| Wittmund | 2006 | 30 | 30 | 70 x Sanyo HIT 210 | 14,7 | 2 x SMA SMC 6000, 1 x SMA SB 2100 TL | kWh | 14945 | 14813 | 15266 | |||
| kWh/kWp | 1016 | 1007 | 1038 | ||||||||||
| Wilhelmshaven | 2008 | -14 | 30 | 6 x Sanyo HIT 215 | 1,29 | 1 X Fronius IG 15 | kWh | 372 | 910 | ||||
| kWh/kWp | 288 | 705 | |||||||||||
| Wilhelmshaven | 2008 | 0 | 50 | 24 x Sanyo HIT 215 | 5,16 | 1 x Fronius IG 60 HV | kWh | 120 | 5490 | ||||
| kWh/kWp | 23 | 1063 | |||||||||||
| Wilhelmshaven | 2009 | 31 | 50 | 18 x Sanyo HIT 205 | 3,69 | 1 x Fronius IG Plus 50 | kWh | 3251 | |||||
| kWh/kWp | 881 | ||||||||||||
| Rheurdt | 2005 | -17 | 30 | 24 x Sanyo HIT 190 | 4,56 | 1 x Fronius IG 40 | kWh | 4070 | 4540 | 4400 | 4430 | 4440 | |
| kWh/kWp | 892 | 995 | 965 | 971 | 973 | ||||||||
| Schwerin, je 6 Anlagen zu | 2005 | 45 | 38 | 24 x Sanyo HIT 210 | 5,04 | 1 x Fronius IG 60 | kWh | 0 | 4500 | 4600 | 4610 | 4750 | |
| kWh/kWp | 0 | 892 | 912 | 914 | 942 | ||||||||
| Schwerin, je 6 Anlagen zu | 2005 | 45 | 38 | 12 x Sanyo HIT 210 | 2,52 | 1 x Fronius IG20 | kWh | 0 | 2150 | 2200 | 2200 | 2300 | |
| kWh/kWp | 0 | 853 | 873 | 873 | 912 | ||||||||
| Schwerin | 2005 | -4 | 38 | 36 x Sanyo HIT 210 | 7,56 | 2 Fronius IG 40 | kWh | 0 | 7786 | 7687 | 7645 | 7902 | |
| kWh/kWp | 0 | 1029 | 1016 | 1011 | 1045 | ||||||||
| Schwerin | 2005 | -4 | 38 | 12 x Sanyo HIT 210 | 2,52 | 1 Fronius IG 20 | kWh | 0 | 2481 | 2465 | 2450 | 2530 | |
| kWh/kWp | 0 | 984 | 978 | 972 | 1003 | ||||||||
| Oldenburg | 2006 | 3 | 30 | 38 x Sanyo HIT 210 | 7,98 | 2 x Fronius IG 40 | kWh | 2867 | 7795 | 6456 | |||
| kWh/kWp | 359 | 976 | 808 | ||||||||||